Heat Pump Running but Not Cooling? Diagnose & Fix It Fast

Heat Pump Running but Not Cooling? Diagnose & Fix It Fast Oct, 12 2025

Ever notice your heat pump is humming, the fan is blowing, yet the air stays warm? That frustrating moment usually means something’s gone sideways inside the system. Below we break down why a heat pump can run without cooling, walk you through a DIY diagnosis, and tell you when it’s time to call in a pro.

Key Takeaways

  • Most “running‑but‑no‑cooling” issues stem from low refrigerant, thermostat missettings, or a blocked coil.
  • Run a systematic checklist: thermostat, filters, outdoor coil, fan motor, and defrost cycle.
  • Simple fixes like cleaning filters or resetting the thermostat can restore cooling within minutes.
  • If the compressor clicks but doesn’t engage, or you smell refrigerant, professional service is required.
  • Regular seasonal maintenance prevents repeat failures and extends equipment life.

How a Heat Pump Works (In Plain English)

A heat pump is essentially a reversible refrigerator. In cooling mode, the compressor pressurizes the refrigerant, turning it into a hot, high‑pressure gas. This hot gas then travels to the outdoor coil where it releases heat to the outside air and becomes a cooler liquid. The cooled liquid moves inside to the indoor coil which acts as an evaporator, absorbing indoor heat and turning the refrigerant back into a gas. The fan motor circulates air across the indoor coil, delivering chilly air into your rooms. The whole loop repeats until the thermostat signals the desired temperature.

Why It Might Run Without Cooling

If any part of that loop stalls, the heat pump can keep its motor humming while the air stays warm. Here are the most common culprits:

  • Thermostat settings or sensor errors - a summer‑mode setting, wrong fan speed, or a dead sensor can prevent the system from entering cooling mode.
  • Low or leaked refrigerant - without enough refrigerant, the indoor coil can’t absorb heat.
  • Clogged outdoor coil - leaves, dust, or ice block heat exchange, causing the compressor to overheat and shut down.
  • Dirty or restricted air filter - reduces airflow, making the coil too warm to cool effectively.
  • Faulty compressor - electrical or mechanical failure means the refrigerant never gets pressurized.
  • Defrost cycle mis‑timing - in cold climates the system pauses cooling to melt ice; a stuck defrost can keep the pump running but not cooling.
  • Fan motor problems - if the outdoor fan doesn’t spin, the coil can’t shed heat, triggering a shutdown.
Homeowner checking thermostat, cleaning filter, and clearing outdoor coil.

Step‑by‑Step Troubleshooting Guide

  1. Check the thermostat. Make sure it’s set to “Cool” and the temperature is lower than the current room temp. Verify the fan is on “Auto," not “On" which can keep the unit running continuously.
  2. Inspect the air filter. Remove the indoor filter; if it looks gray or crusty, replace it. A clean filter restores proper airflow.
  3. Look at the outdoor unit. Turn off power, then clear any leaves, twigs, or debris from the coil. Spray a garden hose lightly to wash away dust - avoid high pressure which can bend fins.
  4. Listen for the compressor. When the system calls for cooling, you should hear a distinct click followed by a humming sound. If you only hear the fan, the compressor may be dead or protection‑locked.
    • Smell a sweet, chemical odor? That indicates a refrigerant leak - stop using the unit and call a technician.
  5. Check the fan motor. With the power off, spin the outdoor fan blade by hand. It should turn freely; resistance may mean a burned motor or stuck capacitor.
  6. Observe the defrost cycle. In winter, the unit may briefly stop cooling while it defrosts. If you notice the outdoor unit flashing a “DEFROST” light for more than 15 minutes, the sensor could be stuck.
  7. Measure refrigerant pressure (if you have tools). A low‑side gauge reading below 45 psi in cooling mode usually points to a leak.
    • Never add refrigerant yourself - it requires EPA‑certified handling.
  8. Reset the system. Turn off the breaker for 2 minutes, then power it back on. Most modern heat pumps clear minor electronic glitches after a hard reset.

If after these steps the air is still warm, you likely have a deeper mechanical issue.

Comparison Table: Common Symptoms vs. Likely Causes

Symptoms and probable root causes for a heat pump that runs but doesn't cool
Symptom Most Probable Cause Quick Fix
Unit runs, air stays warm Thermostat set to heat or fan‑only Switch to Cool mode, lower set point
Humming sound, no cold air Low refrigerant Call certified HVAC tech for leak repair
Outdoor fan not spinning Faulty fan motor or capacitor Inspect motor, replace capacitor if burnt
Unit shuts off after a few minutes Clogged outdoor coil causing overheating Clean coil, ensure proper clearance
Continuous running, no cooling cycles Stuck defrost timer Reset timer or replace controller
HVAC technician inspecting a heat pump with tools and gauges.

Maintenance Tips to Keep Your Heat Pump Cooling Efficiently

  • Schedule a professional tune‑up before each cooling season. Technicians will check refrigerant charge, electrical connections, and coil cleanliness.
  • Replace the air filter every 1‑3 months during heavy use to ensure unobstructed airflow.
  • Trim vegetation at least 2 feet away from the outdoor unit. Good clearance improves heat rejection.
  • Run the fan on “Auto” instead of “On” to let the system cycle off when cooling isn’t needed, reducing wear.
  • Check the condensate drain annually; a clogged drain can cause high‑humidity shut‑offs that mimic a cooling failure.

When to Call a Professional

DIY can solve most airflow and thermostat hiccups, but certain problems need licensed expertise:

  • Refrigerant leaks or low charge - handling refrigerant requires EPA certification.
  • Compressor makes loud knocking or fails to start - the compressor is the heart of the system; replacement is costly.
  • Electrical control board faults - diagnosing voltage levels and replacing boards is a job for an electrician‑qualified HVAC tech.
  • Persistent defrost cycle errors - may involve sensor replacement or firmware updates.
  • Any smell of gas, oil, or burnt wiring - turn off the unit and evacuate the area, then call emergency service.

Remember, attempting to open sealed refrigerant lines or tamper with high‑voltage components can void warranties and be dangerous.

Frequently Asked Questions

Why does my heat pump run continuously but never reaches the set temperature?

A continuous run often means the thermostat is set to “Fan‑On” or the outdoor coil is too dirty to release heat, causing the system to overheat and shut down before cooling properly.

Can I add refrigerant myself to fix a low‑charge problem?

No. Adding refrigerant requires special equipment and certification. A DIY addition can damage the compressor and is illegal under EPA rules.

What does a frozen outdoor coil feel like, and how do I thaw it?

The coil will feel solidly ice‑covered and the fan may stop spinning. Switch the system to “Defrost” mode if available, or turn the unit off and let it melt naturally. Never use a hair dryer - it can melt fins unevenly.

Is it normal for the fan to run after I turn off the thermostat?

Yes. Many heat pumps have a post‑cooling fan cycle that continues for a few minutes to clear residual humidity and protect the indoor coil.

How often should I schedule professional maintenance?

At least once a year, preferably before the cooling season. This ensures the refrigerant charge, electrical connections, and heat exchange surfaces are in optimal condition.

By running through this checklist, most homeowners can pinpoint why their heat pump not cooling situation occurs and either fix it quickly or know exactly what to tell the technician. Regular upkeep and smart thermostat settings go a long way toward keeping your indoor climate comfortable all summer long.